1p DC Miniature Circuit Breaker Non Polarized DC Breaker with TUV Certificates From 1A to 63A

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
17
Year of Establishment
2009-03-06
  • 1p DC Miniature Circuit Breaker Non Polarized DC Breaker with TUV Certificates From 1A to 63A
  • 1p DC Miniature Circuit Breaker Non Polarized DC Breaker with TUV Certificates From 1A to 63A
  • 1p DC Miniature Circuit Breaker Non Polarized DC Breaker with TUV Certificates From 1A to 63A
  • 1p DC Miniature Circuit Breaker Non Polarized DC Breaker with TUV Certificates From 1A to 63A
  • 1p DC Miniature Circuit Breaker Non Polarized DC Breaker with TUV Certificates From 1A to 63A
  • 1p DC Miniature Circuit Breaker Non Polarized DC Breaker with TUV Certificates From 1A to 63A
Find Similar Products

Basic Info.

Model NO.
JB-1P
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Magnetic
Installation
Fixed
Structure
MCB
Poles Number
1
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Overcurrent Protection
Certification
ISO9001-2000, CE, CCC, TUV
Mini Circuit Breaker Rated Voltage
250 VDC
Mini Circuit Breaker Rated Current
1,2,3,4,6,10,16,20,25,32,40,50,63A
Mini Circuit Breaker Brand
Langir
Mini Circuit Breaker Is_Customed
Yes
Certificate
TUV
Transport Package
12 PCS Per Box
Specification
CE, IEC
Trademark
Langir
Origin
Wenzhou
HS Code
853620000
Production Capacity
50000 Set/Month

Product Description

The JB is a DC circuit breaker dedicated to multi string photovoltaic installations.

Storage -40 to 85 degree
- This circuit breaker is designed to protect the cables located between each string of photovoltaic modules and the photovoltaic inverter against overloads and short circuits (see application diagram).
- Combined with a switch , the JB will be installed in a string PV protection enclosure at the end of each string of photovoltaic modules.
- It can be locked (by a padlocking device) in OFF position as a safety measure for removal of the PV inverter.
- Since a fault current can flow in the reverse direction to the operating current, the JB can detect and protect against any bidirectional current.
- To ensure the safety of the installation, it is necessary, depending on the various types of application, to combine the JB with:
a residual current device at the AC end
a fault passage detector (insulation monitoring device) at the DC end
an earth protection circuit breaker at the DC end
- In all cases, fast action on site will be required to clear the fault (protection not ensured in the event of a double fault).
- JB is not polarity sensitive: (+) and (-) wires can inversed without any risk.
- The JB is: delivered with three inter-pole barrier to provide increased isolation distance between two adjacent connectors

Main characteristics

Operating Voltage (Ue) 1P=250 V DC, 2P=500 V DC
3P=750 V DC, 4P=1000 V DC
Rated insulation voltage (Ui) 1,000 VDC
Breaking capacity (Icu) 10 kA
Impulse voltage (Uimp) 4 kA
Electrical connection By the bottom for In and Out
Number of poles 1P, 2P, 3P, 4P
Standards IEC 60947-2
EN 60947-2
Rated service breaking capacity (Ics) 100% of the Icu
Endurance (O-C) Electrical 1,500 cycles (where L/R=2 ms)
Mechanical 20, 000 cycles
   
Mechanical 20, 000 cycles
Degree of pollution 2
Category A (no delay in accordance with IEC / EN 60947-2 standards)
Degree of protection
(IEC 60529)
IP40
Tropicalisation Relative humidity: 95% at 55 degree in accordance with
IEC 60068-2 and GB 14048.2 standards
Temperature Operating -25 to 70  degree
Storage -40 to 85 degree

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier